# Asbestos and lead before renovation work

Pre-works asbestos survey, DTA, CREP: what French law requires before renovating an older building and which documents to give the contractor.

*Author : The TIMSTROY team · Published 2026-10-04 · Category : Guides*

In France, before works, the person who commissions them must have asbestos searched for as soon as the operation may expose workers; for lead, a constat de risque d’exposition au plomb (CREP, lead exposure risk report) is required to sell or let a home built before 1 January 1949, and before certain works on the common parts of a building.

## Who must have asbestos surveyed before the works?

The donneur d’ordre (the party ordering the works), the maître d’ouvrage (the client) or the owner has asbestos searched for before any operation involving a risk of exposure for workers (art. L4412-2 of the French Labour Code, Code du travail). This is the repérage amiante avant travaux, or RAT (pre-works asbestos survey). The order (arrêté) of 16 July 2019 defines the donneur d’ordre as the individual or legal entity that has the operation carried out: a private individual who orders works is therefore concerned.

The survey is entrusted to a certified surveyor (opérateur de repérage certifié), based on the detailed programme of works and the available plans. Where applicable, the report states the presence, nature and location of materials containing asbestos; it is attached to the documents given to the contractors.

## Which buildings are concerned?

The Labour Code does not set a single date: the risk is assessed according to the works. Article R4412-97 refers in particular to buildings and materials built or manufactured before the asbestos ban came into force on 1 January 1997. The date of 1 July 1997, which applies to the building permit, comes from the French Public Health Code (Code de la santé publique): asbestos files for buildings and the asbestos diagnosis for a sale.

## Is the DTA or the sale diagnosis enough?

Not always. For buildings whose building permit was issued before 1 July 1997, the Public Health Code provides for the dossier technique amiante (DTA, technical asbestos file) for the common parts, kept by the owner or the syndicat des copropriétaires (the co-owners’ association), the dossier amiante des parties privatives (DA-PP, asbestos file for the private parts) of each co-owner, and the état amiante (asbestos report) attached to the sale.

These documents are not drawn up for a specific programme of works. The INRS, the French institute for occupational health and safety, points out that they do not always make it possible to determine the presence of asbestos that is not directly accessible. A survey can only be avoided if the available information is precise enough for the materials the works will affect (article 3 of the order of 16 July 2019).

## What happens if asbestos is found?

Asbestos removal and encapsulation, governed by sub-section 3 of the Labour Code, must be entrusted to a certified company (art. R4412-129); its plan is in principle sent at least thirty days before work starts (art. R4412-137). Other work on materials likely to release fibres falls under sub-section 4: without this certification, but with a written work procedure (mode opératoire) and trained workers.

A discovery can therefore change the programme, the order of the works and the schedule. When such works are needed, they are entrusted to authorised contractors; how they are organised is decided with you before the rest of the works continue.

## Is a lead diagnosis needed before works?

The CREP identifies coatings containing lead (art. L1334-5 of the Public Health Code). For a home built before 1 January 1949, it is mandatory to sell or let, and for works to remedy unfit housing (sortie d’insalubrité). In a residential apartment building of that period, it is also required before works on the common parts that may substantially damage the coatings (art. L1334-8).

If the CREP finds deteriorated coatings containing lead above the regulatory threshold, set at 1 mg/cm², the owner must inform the occupants and anyone who will carry out works in the building or the part of the building concerned (art. L1334-9).

## What precautions should be taken when lead is present?

Scraping, sanding or stripping lead paint produces dust. The ARS Auvergne-Rhône-Alpes (regional health agency) recommends never dry-sanding old coatings, avoiding heat stripping and cleaning with a damp cloth; young children and pregnant women should not be present during the works. The INRS asks contractors to use techniques that produce as little dust as possible and vacuum cleaners with high-efficiency filters.

## What should I prepare before the on-site consultation?

We ask for the available diagnoses during the on-site consultation: they help identify early the areas to check. Gather the DTA or its summary sheet (fiche récapitulative, from the syndic, the building manager, in a co-ownership), your DA-PP, the diagnoses provided at purchase or when renting, earlier survey reports and the plans.

A missing survey must still be commissioned by the donneur d’ordre before the works concerned. For access and co-ownership, also read [our guide to renovating an older Paris home](/en/articles/coulisses-chantier-haussmannien/).

## What to check before the works

- The date of the building permit or the year of construction is known.
- An asbestos survey covers the planned programme, or the existing documents are sufficient for the materials affected.
- The DTA, the DA-PP and the sale diagnoses have been gathered.
- A CREP is available if the home dates from before 1949, and for the common parts if works affect them.
- The reports are sent to the contractor before the quote is drawn up.
- Young children and pregnant women stay away during works on lead paint.
- Any asbestos removal or encapsulation is entrusted to a certified company.

Are your documents ready? [Tell us about your project](/en/devis/).

## Official sources (in French)

- [Labour Code, art. L4412-2: pre-works survey](https://www.legifrance.gouv.fr/codes/article_lc/LEGIARTI000033013763)
- [Labour Code, art. R4412-97](https://www.legifrance.gouv.fr/codes/article_lc/LEGIARTI000038322515)
- [Order of 16 July 2019 on asbestos surveys in buildings](https://www.legifrance.gouv.fr/loda/id/JORFTEXT000038777498)
- [Labour Code, sub-section 3: asbestos removal and encapsulation](https://www.legifrance.gouv.fr/codes/section_lc/LEGITEXT000006072050/LEGISCTA000018490630/)
- [Public Health Code: asbestos in buildings](https://www.legifrance.gouv.fr/codes/id/LEGISCTA000024140902)
- [Public Health Code, art. L1334-5: lead exposure risk report](https://www.legifrance.gouv.fr/codes/article_lc/LEGIARTI000031928095)
- [Public Health Code, art. L1334-8: works on common parts](https://www.legifrance.gouv.fr/codes/article_lc/LEGIARTI000031928065)
- [Public Health Code, art. L1334-9: lead and works](https://www.legifrance.gouv.fr/codes/article_lc/LEGIARTI000037671590)
- [Service Public: housing containing asbestos](https://www.service-public.gouv.fr/particuliers/vosdroits/F288)
- [Service Public: asbestos diagnosis for a sale](https://www.service-public.gouv.fr/particuliers/vosdroits/F742)
- [Service Public: lead exposure risk report](https://www.service-public.gouv.fr/particuliers/vosdroits/F1142)
- [INRS: asbestos regulations](https://www.inrs.fr/risques/amiante/reglementation.html)
- [INRS: preventing exposure to lead](https://www.inrs.fr/risques/plomb/ce-qu-il-faut-retenir.html)
- [ARS Auvergne-Rhône-Alpes: lead and works in the home](https://www.auvergne-rhone-alpes.ars.sante.fr/exposition-au-plomb-et-saturnisme-risques-et-conseils-pour-sen-proteger-logement-travaux-activites)

Verified on 4 October 2026.

## Contact and quote

- Online quote request : https://www.timstroy.fr/en/devis/
- Email : contact.timstroy@gmail.com
- Phone : 07 68 71 21 66 (+33768712166)
- Service area : Paris, Hauts-de-Seine, Seine-Saint-Denis, Val-de-Marne
- Site languages : Français, English, Русский, Українська
- TIMSTROY is not currently RGE-certified: its quotes do not qualify for subsidies that require this certification. Consult France Rénov’ to check the conditions for your project.

A first reply within two working days, then a free on-site consultation.

---

Page : https://www.timstroy.fr/en/articles/amiante-plomb-avant-travaux/

Other languages : [Français](https://www.timstroy.fr/fr/articles/amiante-plomb-avant-travaux/) · [Русский](https://www.timstroy.fr/ru/articles/amiante-plomb-avant-travaux/) · [Українська](https://www.timstroy.fr/uk/articles/amiante-plomb-avant-travaux/)